Reducing air conditioning condenser noise
As residential areas become denser and houses are built closer together, noise from air conditioning condensers is a growing concern. Condensers are often installed alongside homes, under eaves, with neighbouring bedrooms just beyond a fence—leading to sleep disturbances and noise complaints to local councils. Controlling the noise from air conditioning compressors is essential for maintaining a peaceful home and neighbourhood.
Most councils enforce noise regulations requiring plant equipment (e.g., air conditioners and pool pumps) to remain within 5 dB(A) or 3 dB(A) above ambient noise levels.
We frequently receive inquiries about reducing A/C unit noise. This guide provides general recommendations based on our extensive experience and past projects. However, Megasorber is an acoustic material manufacturer—not an acoustic consultancy—and installing a Megasorber enclosure does not guarantee compliance with council regulations.
Each case is unique. Consult the air conditioning unit manufacturer to ensure the enclosure meets their service and airflow requirements. Additionally, a registered acoustic consultant to verify compliance with local council regulations.
Acoustic enclosure with unique Megasorber air inlet and outlet designs
Air conditioning condensers vary in design and capacity, requiring customised noise reduction approaches. Megasorber has developed innovative, copywritten acoustic enclosure designs featuring unique air-inlet and air-outlet configurations. These designs optimise noise reduction while maintaining sufficient airflow for condenser performance.
Key design features
- Enclosure Material: 9mm fibre cement sheet.
- Air Inlet Design: Located at the bottom of the enclosure.
- Air Outlet Design: Two acoustic baffles above the A/C unit with a top cover panel.
Important: The two acoustic baffle panels must have at least 30% overlap. - Interior Lining: Megasorber P50G-RG (or FM50W-RG) acoustic panel for superior noise absorption.
Important: Every setup is unique. These designs should be tailored to your specific requirements. Below is an example of an enclosure layout for an Actron CRA 130T AC Unit.
(1) Manufacturer service and airflow requirements
(2) The enclosure details
Acoustic performance estimates
The effectiveness of noise reduction depends on several factors, including the A/C unit type, enclosure design, and site conditions.
Sound absorption
Megasorber P50G-RG (or Megasorber FM50) is a 50mm thick acoustic panel with patented sound absorption technology that reduces condenser fan noise.
Key benefits
- Exceptional sound absorption for condenser fan noise.
- Non-combustible, water-repellent, and highly durable Soundmesh G8 facing—ideal for outdoor applications.
- Designed for exposed environments, ensuring longevity and performance.
Installation tips
- Fix Megasorber P50G-RG directly with Megasorber A200 adhesive.
- Cover all edges with metal trim (e.g., Colorbond) to minimise water ingress.
Sound transmission loss (Rw) estimates
Below is an example of typical Rw + Ctr values for 9mm fibre cement sheet (FCS) enclosure panels lined with Megasorber P50G-RG acoustic panels.
Important notes:
- The table represents the calculated sound transmission loss of the panels, not the total noise reduction of the entire enclosure system.
- Actual performance varies based on the enclosure’s design, A/C unit specifications, and site conditions.
- For an accurate assessment, consult the air conditioning unit manufacturer and/or a registered acoustic engineer.
Aesthetics
There are various finishes available depending on your preference. See below these previous installations as an example of an adaptation of our enclosure.

Adaptation & performance
The full enclosure may not be required or practical in all situations. The schematic should be adapted to your specific unit location and surrounding walls, fence or other structures that may impact the reverberation of noise. As each unit and enclosure will perform differently, it is difficult to provide a specific estimate of the expected reduction in noise.
For specific recommendations, please contact the unit manufacturer or a registered acoustic consultant.
Further information
As each project has different requirements, this information should be used as a guide only.
Please contact the Megasorber team with any specific enquiries for additional information and recommendations.