Acoustic treatment for office meeting room

Project requirements

  • Meeting room with high reverberation levels
  • Speech intelligibility in meetings / teleconferences impacted
  • Glass & plasterboard walls, exposed concrete soffit
  • Solution to focus on key speech frequencies
  • Finish must be aesthetically pleasing as well as functional.

Product features

  • Superior sound absorption using patented technology.
  • BCA Group 2 fire classification
  • 100% recyclable acoustic polyester wool
  • Water repellent facing.
  • Excellent thermal insulation.
  • Long service life.
  • Easy to install – direct fix using Megasorber A200 adhesive.
  • Easy to clean facing.

Megasorber P
P100G-RW 100mm acoustic polyester panel with water repellent Soundmesh® G8 facing (White).

Product installation

  • Direct-fix with Megasorber A200 onto concrete soffit.
  • Panels custom cut to 1200 x 600mm.

Finish

Shadow line finish, with 20mm gap between panels.

The project

Project: Renzo Tonin Melbourne Office Meeting Room
Location: Gladsone Street, South Melbourne Victoria

Download the full case study View the technical data sheet

View Gallery

Renzo Tonin Melbourne

Acoustic results

Reverberation time measured by acoustic engineer at Renzo Tonin & Associates before and after installation of panels.

Australian Standard 2107:2000 recommends maximum reverberation time between 0.6 and 0.8 seconds for such spaces.

Before installation:

Reverberation time at key speech frequencies (250-2000 Hz) up to 1.3 seconds

After installation:

Reverberation time at key speech frequencies reduced to 0.4-0.7 seconds